Electro-Surgical unit/Surgical Diathermy/Cautery

BR Biomedicals  
vr pleased to introduce a new Electro-Surgical unit for cuting and coagulation called "Honest High Frequency Wave Operation Unit" from Japan, Wich is the best device for the treatment of erosion of cervix.

Joule-heated cutting and coagulation ability...
Demonstrates its excellent capability at various medical on-sites.

Surgical Operating Devic
5 Features of Honest MGI-202
    BR
  1. Using 6.05MHz frequency with low voltage and resistance provides smooth and effective medical treatment, cut and coagulation.
  2. Deterrence of carbonization due to arc discharge by means of low voltage output able to cut and coagulate with tissue being boiled and less transformed.
  3. No need switching-over of the wave mode between the operations of cutting and coagulation because using only Medium type Oscillating Wave Pattern.
  4. Can be operated also in the liquid.
  5. Continuous out-put of the electric current is almost unlimited.
Principle for Resection and Coagulation
When the area of electrode (a guide-tip) is made very small (needle-shaped or looped needle-shaped), electricity converges on the guide-tip and high temperature heat is generated between the guide-tip and tissues. The heat blows up the tissues and eventually dissects them. You can make conization resection by turning around the guide-tip. Since resected pieces are not affected and changed in quality by discharge of arc, they are clearly observed.
Bleeding from the region after resection can surely be stopped by the oblate-shape guide-tip.

Surgical Method by using Conization Guide-tip
  1. The hip of a person is tightly put on the return electrode.
  2. Opening of uterus becomes exposed in cusco speculum, both guide-tip for coagulation and conization are attached to the handpieces.
  3. Electrify the metal wire part of triangle conization guide-tip, and turn round in 360 degree to resect the region as a conization sample.
  4. Start resection from a position of 9 o’clock if the lesion is located at upper prolabium while starting from a position of 3 o’clock if the lesion is located at the lower place.
  5. For coagulating and necrotizing the region which is possibly remained dysplasia, coagulate firmly by means of the 5mm dia. oblate-shape guide-tip.
  6. (This is “Radical High Frequency Wave Surgery for Conization”.)

    It will take 10 seconds to resect and the aggregated time including coagulating and arresting bleeding will be 3-5 minutes.
Click here to Download PDF Brochure