Physiotherapy & Rehabilitation » Electrotherapy & Combi Therapy
Electrotherapy & Combi Therapy
 |
|
|
|
| 2-Channel Electrotherapy/Multi-Frequency Ultrasound Combo: EU - 920 |
| |
|
It has Multi frequency ultrasound (1/3 MHz, each probe) and different stimulation modes such as 2 or 4-pole IF, EMS, Russian, TENS, Hi-Volt, Microcurrent, and DC. It can be used as independent electrotherapy or ultrasound or in combination of US and ES. Ultra sound has Very low BNR i.e. according to IEC |
 |
| Beam Nonuniformity Ratio (BNR)-ratio between peak amplitude and the average amplitude of the ultrasound beam across the ERA |
a. The lower the BNR, the more uniform the intensity of the sound wave
b. Lower BNR minimizes the risk of "hot spots" and allows for higher doses to be applied
c. Acceptable BNR range is between 2 and 5 (must be listed on all units)
|
 |
| Click here to Download PDF Brochure |
|
|
|
 |
|
|
 |
|
|
|
| Suction Unit: SU - 520 |
| |
| Blow-out (ejector) vacuum system: No water reservoir is needed. It is virtually maintenance-free, since dust or moisture does not adhere inside the tube or on the connections, resulting in preventing blockages and oxidation. Reusable sponge disks ordisposable paper disks can be used in the vacuum electrode. Connectable to the EU-940, the ES-520 or the ES-521 electrotherapy unit |
 |
| Click here to Download PDF Brochure |
|
|
|
 |
|
|
 |
|
|
|
| D4 Combi |
| |
Combined three-frequency ultrasound and dual-channel interferential, diadynamic and TENS current unit
DITER D4 COMBI is safe and versatile combination unit which contains features of three-frequency ultrasound unit and dual-channel electrotherapy unit. The features can be applied separately (even at the same time) or as combination therapy.
In ultrasound application three different frequencies are obtained from the same treatment head. Low 0.9 MHz frequency can be applied for treating areas deep in tissue whereas 2 MHz and 3 MHz frequencies are for more superficial areas.
In combination therapy the treatment head acts as an electrode and ultrasound is combined to bipolar interferential or TENS current.
Specifications
- three ultrasound frequencies
- continuous / pulsed ultrasound
- selectable pulse rate and duty cycle
- four pole interferential (with automatic vector scan option)
- bipolar interferential
- symmetric biphasic TENS
- monophasic TENS
- constant current / constant voltage selection in TENS mode
- TENS currents: continuous, intermittent, burst and modulated
- diadynamic currents (MF, DF, CP, CP-id, LP, RS, MM)
- square / triangular pulse
- combined carrier and diadynamic current for combination treatment
- galvanic direct current
- combined carrier and galvanic direct current for combination treatment
- Träbert´s 2-5 current
- 9 pre-programmed diadynamic protocols
- I/T diagnostics
- pre-programmed basic settings which are fully adjustable by the operator
|
|
|
|
 |
|
|
|